Acer AT2645 LCD TV Service Menu

Acer AT2635B , Acer AT2645 and Acer AT2646 Service mode.
Approximately 30 minutes should be allowed for warm up before proceeding white balance adjustment.
YPbPr Mode display adjustment White balance adjustment (B)

General set-up :
Equipment Requirements: Minolta CA-110 or Equivalent Color analyzer Quantum Data Pattern Generator 802G , 802BT or equivalent instrument Input requirements:
Input Signal Type: YPbPr signal
1. 720P mode, TVBar100 pattern by 802G or 802BT.
2. Select Smart picture to User mode and check the x, y data.
Input Signal Strength: 1 Vpp for Y signal; 700 mVpp for Pb & Pr signal
Input Injection Point: YPbPr (RAC jack)

Acer LCD tv service mode
Photo credit to www.inisdesign.com

Acer AT2635B , Acer AT2645 and Acer AT2646 Color temperature Standard/Warm/Cold (x, y) co-ordinates specification:
Picture Mode x Y
Normal (10000oK) 0.281±0.003 0.288±0.003
Warm (8000oK) 0.295±0.003 0.305±0.003
Cold (13000oK) 0.269±0.003 0.274±0.003

Alignment method Acer AT2635B , Acer AT2645 and Acer AT2646:
Initial Set-up:
1. Select source as “VGA”.
2. Set Contrast = 50 (CMO) and Brightness=50 (CMO) , at Standard menu mode.
3. Apply “PGCWRGB”(pattern-1) pattern by VGA pattern generator.
4. Enter factory mode menu: press “MENU+ “234” then enter FAC mode
Alignment:
1. At FAC mode menu, select FACTORY->Picture ->ADC -> Auto Colour item. Then press “>” key to adjust
ADC_GAIN_R, ADC_GAIN_G, ADC_GAIN_B and ADC_OFFSET_R, ADC_OFFSET_G, ADC_OFFSET_B. Then
store those values to NVM.