Hisense LCD model 22V87. Chassis: MST6E16JS
To enter the Factory OSD Menu
With factory RC (remote control)
Press “M” button and enter factory mode.
Press “Menu” button and enter factory OSD menu.
Press “CH+”/“CH-” button select the function menu, press “VOL+”/“VOL-” enter the selected function menu. Press “VOL+”/“VOL-” button adjust values in the menu.
Press “M” button exit factory mode in the factory OSD menu.
When TV outgoing factory,user can not enter factory OSD menu with Factory Remote With user’s RC
Power TV On
Press Menu button and call up User OSD Menu
Select Sound-> Balance
When Balance value is “0”, Enter 0->5->3 ->2 in sequence.
Photo credit : tmoml.com
Note:
Factory OSD appears.
Press the standby button then AC turn off and restart the TV, which can exit factory OSD
menu.
Factory OSD Menu
The Factory OSD Menu comprises Factory Menu and Design Menu .
FACTORY MENU
WHITE BALANCE
ADC ADJUST
LOGO
OSD LANGUAGE
COUNTRY
OPTIONS
FACTORY INIT
TEST PATTERN
VERSION
NON STANDARD
ADC ADJUST
Only in component and VGA
SOURCE ,The “ADC Adjust”
Can be chosen.
LOGO
NULL
HISENSE
WELCOME
OPTION
SOURCE TV
TOFAC M
ATS 1
STARTUP MENU 1
Search Sensitive 1
RF NTSC 0
HDCP OUT OR IN 1
FACTORY INIT
QINGDAO
HUANGDAO
HUNGARY
FRANCE
AUSTRALIA
CLEAR PROTECTLY
CLEAR UNPROTECTLY
DESIGN MENU
PICTURE MODE
SOUND MODE
PICTURE CURVE
AUDIO CURVE
SSC SETTING
SAVING MODE
PICTURE MODE
MODE STANDARD
BRIGHTNESS 50
CONTRAST 50
COLOUR 50
SOUND MODE
MODE USER
120HZ 10
500HZ 10
1.5KHZ 10
5KHZ 10
10KHZ 10
PICTURE CURVE
MODE BRIGHTNESS
CURVE 0 97
CURVE 25 105
CURVE 50 120
CURVE 75 130
CURVE 100 141
AUDIO CURVE
MODE VOLUME
CURVE 0 0
CURVE 25 18
CURVE 50 22
CURVE 75 28
CURVE 100 36
SSC SETTING
DDR SSC 2
DDR MCM 60
LVDS SSC 2
LVDS PCM 60
SAVING MODE
255