Zenith | Author | July 04, 2015

Zenith 32/37/42LC2DA 

Application Object
These instructions are applied to all of the Zenith LCD or LG TV using chassis LA63E.
2. Notes
(1) Because this is not a hot chassis, it is not necessary to use an isolation transformer. However, the use of isolation transformer will help protect test equipment.
(2) Adjustments must be done in the correct order.
(3) The adjustments must be performed in the circumstance of 20±5°C of temperature and 65±10% of relative humidity if there is no specific designation.
(4) The input voltage of the receiver be must kept 110V, 60Hz when adjusting.
(5) The receiver must be operational for about 15 minutes prior to the adjustments.
Perform preliminary operation after receiving 100% White Pattern (06CH).
(Or 3. White Pattern status of Ez-Adjust) White Pattern entry method
A) Enter into Ez-Adjust by pressing the ADJ key on the adjustment Remote Control.
B) 100% FULL WHITE PATTERN appears if pressing the OK key after selecting the 3.WHITE
PATTERN with the CH + / - KEY.
* It is possible to heat run the set without a separate signal generator in this mode.
Caution : Care must be taken as afterimage phenomena may occur about the black level part of
screen If leaving pause image turned on for more than 20 minutes (especially inner digital pattern (13
CH), Cross Hatch Pattern (09CH) with significant black/white contrast).


Service menu Zenith 42LC2DA TV

Zenith 42LC2DA TV Service menu

Photo credit : sissyprissyandmom.blogspot.com


If you turn on a still screen more than 20 minutes (Especially Digital pattern(13 CH), Cross Hatch Pattern), an afterimage may occur in the black level part of the screen.

Zenith 42LC2DA Adjustment
(1) Select Component1 as the input with 100% Horizontal Color Bar Pattern(HozTV31Bar) in 480i Mode
(2) After receiving signal for at least 1 second, press the ADJ Key on the Service R/C to enter the ‘Ez - Adjust’ and select the ‘2. ADC 480i Comp1’.
Pressing the Enter Key to adjust automatically.
(3) When the adjustment is over, 'MST3361 Component Success’ is displayed. If the adjustment has errors, 'MST3361 Configuration Error’ is displayed.
(4) Select Component1 as the input with 100% Horizontal Color Bar Pattern(HozTV31Bar) in 1080i Mode.
(5) After receiving signal for at least 1 second, press the ADJ Key on the Service R/C to enter the ‘Ez - Adjust’ and select
the ‘3. ADC 1080i Comp1/RGB’.
Pressing the Enter Key to adjust automatically.
(6) When the adjustment is over, 'MST3361 Component Success’ is displayed. If the adjustment has errors, 'MST3361 Configuration Error’ is displayed.
(7) After the Component MST3361 adjustment is over, convert the RGB-DTV Mode and display Pattern.
When the adjustment is over, 'MST3361 RGB_DTV Success’ is displayed.
(8) Readjust after confirming the case Pattern or adjustment condition where the adjustment errors.
(9) After adjustment is complete, exit the adjustment mode by pressing the ADJ KEY.
6. EDID(The Extended Display Identification Data)/DDC
(Display Data Channel) Download
This is the function that enables “Plug and Play".

Zenith 42LC2DA HDMI EDID Data Input
Required Test Equipment
1) PC, Jig for adjusting DDC. (PC serial to D-sub Connection equipment)
2) S/W for writing DDC(EDID data write & read)
3) D-Sub cable
4) Jig for HDMI Cable connection

Preparation for Adjustments & Setting of Device
1) Set devices as below and turn on the PC and JIG.
2) Open S/W for writing DDC (EDID data write & read).


Zenith Z50PX2D TV Service menu

Zenith | Author | April 16, 2015
Zenith Z50PX2D PLASMA TV Service mode
Chassis AF-05FD


You need a computer to open the factory mode.
Connect the PC to the television using cable data.
1. Application Object
These instructions are applied to all of the PDP TV, AF-05FD.
2. Notes
(1) Because this is not a hot chassis, it is not necessary to use an isolation transformer. However, the use of isolation
transformer will help protect test equipment.
(2) Adjustments must be done in the correct order.
(3) The adjustments must be performed in the conditions of 25±5°C of temperature and 65±10% of relative humidity if
there is no specific designation.
(4) The input voltage of the receiver be must kept 110V, 60Hz during adjustment.
(5) The receiver must be operational for about 15 minutes prior to the adjustments.
1) After receiving 100% white pattern, the receiver must be operated 15 minutes prior to adjustment. (Or 8. White
Pattern condition in EZ - Adjust)
2) Enter into White Pattern - Pressing POWER ON Key on Service Remote Control (S R/C)
- Enter the Ez - Adjust by pressing ADJ Key on Service Remote Control (S R/C).
- Select the 8. White Pattern using CH +/- Key and press the Enter(Y) Key.
Display the 100% Full White Pattern.
[ The set will display white screen without a signal generator in this mode.


Service menu Zenith Z50PX2D TV

Zenith Z50PX2D TV Service menu

Photo credit : spelnionychmarzenswiatmoj.blogspot.com

(1) Test Equipment: PC, Jig for download
(2) Connect the power of VSC B/D.
(3) Execute download program(iMPACK) of PC.
(4) After executing the hot key on the Programmer, click icon
(5) End after confirming

4. POWER PCB Assy Voltage
Adjustment (Va, Vs Voltage Adjustment)
4-1. Test Equipment : D.M.M 1EA
4-2. Connection Diagram for Measuring
4-3. Adjustment
(1) Va Adjustment
1) Connect + terminal of D.M.M to Va pin of P805 and connect – terminal to GND pin of P805.
2) Adjust RV601 voltage to match that of the label on the Top/Right of the panel. (Deviation : ±0.5V)
(2) Vs Adjustment
1) Connect + terminal of D.M.M to Vs pin of P805 and connect – terminal to GND pin of P805.
2) Adjust RV401 voltage to match that of the label on the Top/Right of the panel. (Deviation : ±0.5V)

5. EDID(The Extended Display Identification Data)/DDC (Display Data Channel) download
This is the function that enables “Plug and Play".
5-1. HDMI EDID Data Input
(1) Required Test Equipment
1) Jig for adjusting PC, DDC. (PC serial to D-sub. Connection equipment)
2) S/W for writing DDC(EDID data write & read)
3) D-Sub cable
4) Jig for HDMI Cable connection
(2) Preparation for Adjustments & Setting of Device
1) Set devices as below and turn on the PC and JIG.
2) Open S/W for writing DDC (EDID data write & read).
(operated in DOS mode)

(1) Select Component1 or Component2 as the input with 100% Horizontal Color Bar Pattern(HozTV31Bar) in 720p
Mode and select ‘Normal’ on screen.
(2) After receiving signal for at least 1 second, press the ADJ Key on the Service R/C to enter the ‘Ez - Adjust’ and select
the ‘2. AD9883A-Set’.
Pressing the Enter Key to adjust with automatic movement.
(3) When the adjustment is over, 'AD9883A Component Success’ is displayed. If the adjustment has errors, 'AD9883A Configuration Error’ is displayed.
(4) After the Component AD9883A adjustment is over, convert the RGB-DTV Mode and display Pattern.
When the adjustment is over, 'AD9883A RGB_DTV Success’ is displayed. If the adjustment has errors, 'AD9883A Configuration Error’ is displayed.
(5) Readjust after confirming the case Pattern or adjustment condition where the adjustment had errors.
(6) After adjustment is complete, exit the adjustment mode by pressing the ADJ KEY.

Required Equipment
(1) Color analyzer (CA-100 or similar product)
(2) Automatic adjustor (with automatic adjustment hour necessity and the RS-232C communication being possible)
(3) Pattern Generator(MSPG-925FA): DVI Output

Adjustment of White Balance
O Operate the Zero-calibration of the CA-100, then attach sensor to PDP module surface when you adjust.
O Manual adjustment is also possible by the following sequence.
(1) Enter ‘Ez - Adjust’ by pressing ADJ KEY on the Service Remote Control.
(2) Select "8. WHITE PATTERN" using CH +/- Key and HEAT RUN at least 30 minutes by pressing the ENTER Key.
(3) Receive the Window pattern signal from Digital Pattern Generator. (AV Input: connect the ‘HDMI’)
(4) After attaching sensor to center of screen, select ‘5. White-Balance’ of ‘Ez - Adjust’ by pressing the ADJ KEY on the Service R/C. Then enter adjustment mode by pressing the
Right KEY (G)


Zenith P50W26 PLASMA TV Service menu

Zenith | Author | April 15, 2015
Zenith P50W26 and Zenit P50W26B PLASMA TV Service mode
Chassis: RF-02CA
Adjustments must be done in the correct order. The adjustment must be performed at 25±5oC of temperature and 65±10% of relative humidity.
The input voltage of the receiver must maintain 110~240V, 50/60Hz while adjusting. Operate the receiver for about 15 minutes prior to the adjustment with 100% white pattern (06CH), or white condition in HEAT-RUN mode.
Enter into HEAT-RUN mode. Press the POWER ON KEY on remote control for adjustment. OSD display HEAT-RUN WHITE and screen display 100% full WHITE PATTERN. Set is activated HEAT-RUN without signal generator in this mode. Single color pattern of HEAT-RUN mode uses to check the PANEL
(RED/BLUE/GREEN).
Caution: If you turn on a still screen more than 20 minutes, an afterinage may occur in the black level part of the screen. (Especially Digital Cross Hatch Pattern), a afterimage may be occur in the black level part of the screen.


TV Service menu Zenit P50W26 PLASMA

Zenith P50W26 PLASMA TV Service menu

Photo credit : www.lkda.org


RGB AUTO CUT-OFF & MIN BIAS
1) If the PDP Module or Power Board was replaced, adjust the Power PCB Assy Voltage prior to any other adjustment.
2) Input Full Back (0 Gray) signal which generated from Pattern Generator into Component input and RGB1 Input part.
3) Press POWER ON KEY on R/C for adjustment and select AUTO-CUT(Cut-off Auto Adjustment).
4) Press Vol. + key.
5) Screen adjustment starts with Full Black screen. Original Window screen will be presented about 5-6 seconds later. And if (OK OSD) appears on the screen, then the Auto Cut-off and Min-Bias adjustment will have been completed.


MAX BIAS ADJUSTMENT
1) Input Full White (255 Gray) signal which generated from Pattern Generator into Component input and RGB1 Input.
2) Press POWER ON KEY on R/C for adjustment and select MAX-BIAS.
3) Press Vol. + key.
4) Original Full White screen will be presented about 1-2 seconds later. And if (OK OSD) appears on the screen then the Min-Bias adjustment will have been completed.

(5) After adjustment, press ¥ key to save adjustment and come out of the adjustment mode.
To check whether the circuit adjustment is operated well or not:
1) Display RGB1 to the Main picture, Component input to the Sub picture in the TWIN PICTURE.
2) To check the MIN-Bias, input Full Black (0 gray) signal into Component input and RGB1 input part at the same time in the Pattern Generator.
3) To check the MAX-Bias, input Full White (255 gray) signal into Component input and RGB1 input part at the same time in the Pattern Generator.
4) Compare Black Level with White Level by eye. And if there is no Level difference, the adjustment is
completed.
Data value, which adjusted in the board, is valid until the VSC Board is dissued and must be protected. For the protection of data, Micom does not permit any more adjustment after completion.
In case of re-adjustment, operate First Value Setting.
Each PCB Assy must be checked by Check JIG Set before assembly. (Especially, be careful Power PCB Assy which can cause fatal Damage to PDP Module.)
POWER PCB ASSY VOLTAGE VA ADJUSTMENT
1) Test Equipment : D.M.M 1EA
2) After receiving 100% white pattern, HEAT RUN.
3) Connect + terminal of D.M.M to Va pin of P805 and connect Ð terminal to GND pin of P805.
4) After turning the VR4, voltage of D.M.M adjustment as same as Va voltage which on label of panel
Right/Top. (Deviation : ±0.5V)
VS ADJUSTMENT
1) Connect + terminal of the D.M.M to Vs pin of P805 and connect - terminal to GND pin of P805.
2) After turning the VR1, voltage of D.M.M adjustment as same as Vs voltage which on label of panel Right/Top. (Deviation : ±0.5V)

ADJUSTMENT OF WHITE BALANCE
Operate the Zero-calibration of the CA-100, then stick sensor to PDP module surface when you adjust. For manual adjustment, it is also possible by the following sequence.
1) Select WHITE PATTERN of HEAT RUN mode by pressing POWER ON KEY on remote control for adjustment then operate HEAT RUN more than 15 minute.
2) Supply 216Gray, 128Gray, 70Gray Level, 50% size length and breadth signal to RGB1 input.
3) W/B adjustment must be adjusted once and follow the sequence of Low Light Middle Light
High Light and then save the adjustment value with o Key.
4) To adjust Low Light, stick sensor to Gray Level(or 20~25 Cd/m2) Pattern, press ADJ Key on R/C for adjustment and press v, x on R/C in adjustment mode to select R-L or G-L, press VOL +, - Key and adjust it until color coordination becomes as below.
X: 0.290±0.003, Y: 0.300±0.003
Color temperature: 8, 500oK±500oK
5) To adjust Middle Light , stick sensor to Gray Level (or 70~75 Cd/m2) Pattern, press ADJ Key on remote control for adjustment and press v, x on remote control in adjustment mode to select R-M or G-M, press VOL +, -
Key and adjust it until color coordination becomes as below.
X: 0.290±0.003, Y: 0.300±0.003
Color temperature: 8, 500oK±500oK
6) To adjust High Light, stick sensor to Gray Level(or 135-140 Cd/m2) Pattern, press ADJ Key on the R/C for adjustment and press v, x on R/C in adjustment mode to select R-L or G-L, press VOL +, - Key and adjust it until color coordination becomes
as below.
X: 0.290±0.003, Y: 0.300±0.003
Color temperature: 8, 500¡K±500¡K
7) Exit adjustment mode using o Key.

DDC DATA INPUT REQUIRED TEST EQUIPMENT
1) A jig for adjusting PC, DDC. (PC serial to Dsub. Connection equipment)
2) S/W for writing DDC(EDID data write & read)
3) D-Sub 15P cable, D-Sub to DVI Connector (Connect to DVI Jack)
PREPARATION FOR ADJUSTMENT
1) Set devices as above and turn the PC, jig on.
2) Put S/W for writing DDC (EDID data write & read) into operation. (operated in DOS mode.)

SEQUENCE OF ADJUSTMENT DDC DATA INPUT FOR ANALOG-RGB
1) Put the set on the table and turn the power on.
2) Connect PC Serial to D-sub 15P Cable of JIG for
DDC adjustment to RGB1 terminal (D-Sub 15Pin).
3) Operate S/W for DDC record and select DDC Data for analog RGB in Model Menu.
4) Operate EDID Write command.
5) Operate EDID Read command and check whether Check Sum is OK.
6) If Check Sum is NG, repeat 3-4.
7) If Check Sum is OK, DDC Data for Analog-RGB input is completed.

DDC DATA INPUT FOR DIGITAL-RGB
1) Connect PC Serial to DVI Cable of JIG for DDC adjustment to RGB2 terminal (DVI Jack).
2) Operate S/W for DDC record and select DDC Data for Digital RGB in Model Menu.
3) Operate EDID Write command.
4) Operate EDID Read command and check whether Check Sum is OK.
5) If Check Sum is NG, repeat 3 & 4.
6) If Check Sum is OK, DDC Data for Digital-RGB input is completed.
COMPONENT OFF-SET ADJUSTMENT
1) Input the signal to HD-STB(SK-010T) and receive 14Ch.
2) Input Video signal and Component 720P, 1080i signal of HD-STB into AV1 and Component input part.
3) Select Twin Picture by pressing ADJ twice on R/C, check component in the main picture and AV1 in the sub picture.
4) Adjust the R-OFFSET, B-OFFSET color impression of component(Main picture) and external Input(Sub picture) same by pressing Volume +,- key.


Zenith TV Service Menu

Zenith | Author | April 08, 2015
Zenith TV Service mode
Turn on the TV
Press and hold the Menu button to Channel time is shown up then press the numbers 9,8,7,6 and Enter.
Press and hold 'Menu' to the menu settings disappear.
Immediately press the 'volume up' and 'Channel down' at the same time.
or
Immediately press the 'Channel up' and 'adjust Up' at the same time.
You are now entered in factory mode.
Use the 'Channel up' or "channel down" to select an item.
Write the old value before the change items.
Volume up and down adjust the value.
When you have made all the adjustments you want to select an item '00 '.
Reset the value back to '00 '. 11. Turn the TV off.

Service Menu Zenit TV

Zenith TV Service Menu





Universal Remote

  • Chunghop RM-168GS code List
  • iWave Supersize Universal Remote
  • Automator URC 200 CD Players
  • Asaki Universal Remote for DVD
  • AMAZONE Universal Remote for DVD

CRT Television

  • Zenit TV Service Menu
  • Hisense HSM 515AV TV Service Menu
  • Grundig CUC 7301 TV Service menu
  • SIERA SG1420 TV Service Menu
  • RCA G27684 TV Service Menu


Plasma Television

  • Samsung HCH 551WX TV Service Menu
  • Beko L5C TFT LCD TV Service Menu
  • Beko LCD PLASMA L6E TV Service Menu
  • Beko Plasma TV Service Menu
  • Samsung Plasma TV Service Menu

LED Television

  • How to enter to Sansui TV Service Menu
  • LG 42LB62 LED TV Service Menu
  • Sanyo LED LCD TV Service Menu
  • How to enter to Telefunken TV Service Menu
  • Konka LED TV Service Menu

LCD Television

  • Hisense LCD 19V87 TV Service menu
  • Insignia NS LCD37HD-09 TV Service menu
  • Hisense K15 Series TV Service Menu
  • Hisense MT5380 TV Service menu
  • Grundig 42PX TV Service Menu


  • FORUM
  • Announce
  • Claim
  • Contributor
  • Universal Remote
  • Terms of Service
  • Privacy Policy
  • About
  • Contact
© 2008 - tvservicemenu. All Rights Reserved